Chemical Testing

Testing of Steels by OES

 

Sl.

Product(s)/ Material of test

Specific tests performed

*Test method/Standard against which tests are performed

Range of testing/ Limits of detection

Accuracy

(±)

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Carbon

 

 

 

Silicon

 

 

Manganese

 

 

Phosphorus

 

 

Sulphur

 

 

Chromium

 

 

 

 

Nickel

 

 

 

Molybdenum

 

 

 

Copper

 

Niobium

 

Titanium

OES/ ASTM E 415-99/ ASTM E 1086-94/

IS 8811-1998/

 IS 9879-1988

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.004 – 0.15%

0.15 – 0.60%

0.60 – 1.70%

 

0.01    – 1.0%

1.0 - 5.0%

 

0.01    – 2.0%

2.0 – 5.0%

 

0.001 – 0.050%

0.05 – 0.50%

 

0.0006 – 0.03%

0.03– 0.30%

 

0.01    – 0.2%

0.2 – 2.0%

2.0 – 10.0%

10.0 – 35.0%

 

0.02  – 0.20%

0.20 – 2.0%

2.0 – 15.0%

 

0.02  – 1.0%

2.0   – 3.0%

3.0– 6.0%

 

0.01            – 1.0%

 

0.01            – 0.5%

 

0.01 – 1.0%

15%

10%

10%

 

15%

10%

 

15%

        10%

 

20%

10%

 

20%

10%

 

20%

10%

5%

2%

 

20%

10%

5%

 

20%

10%

5%

 

20%

 

20%

 

20%

 

 

For further details, please contact:

Director
Prof. S.P. Mehrotra
NATIONAL METALLURGICAL LABORATORY
(Council of Scientific & Industrial Research)
JAMESHEDPUR 831 007
Phone: (0657) 2271715, 2270092, 2271709-14 (PBX)
Fax: (0657) 2270527, 2271251, 2271159
Email: director@nmlindia.org,
Website: www.nmlindia.org

Dr. S. Srikanth
Scientist-In-Charge

NML Madras Centre, CSIR Madras Complex
Taramani, CHENNAI 600 113
Ph: 044 2254 2077, 2254 2529, 2254 2523,
Fax: 044 2254 1027
Email: nmlmc@vsnl.com
Working hours: 9.00 am to 5.30 pm (Monday to  Friday, except
Govt. holidays)

Home   |   CECRI     CEERI  | CSIO   | NEERI   |  NML   |   Library   |   Phone Directory   | News    |  Newsletter   |    Tenders