| The
Temperature calibration facility was established with the sole aim to calibrate and
standardize RTDs and thermocouples of high and low temperature range for a variety of
industries ranging from power plants, steel plants, foundry units, heat treatment shops to
several other small scale industries. |

|
|
- Calibration of thermocouples, devices and temperature measuring instruments from ambient
temperature to 1450 degree Celcius
Master Sensors:
- Type S Thermocouple (Scandura, Italy)
- Type S Thermocouple (ISOTECH, UK)
- SPRT (NPL, India)
- PRT (Scandura, Italy)
Major facilities include
High Temperature Furnace
Thermolyne USA (upto 1500 deg. C and 1700 deg. C)
Dry block calibrator(- 20 to 150
deg.C) Druck DBC 150TC
Dry well calibrator (50 to 650
deg.C) Druck DBC 650TC
ZEREF Triple point cell,
Isothermal Technologies UK(Calibration at absolute zero)
Keithley740 System Scanning
Thermometer Keithley USA
Multifunction calibrator
(EUROTRON-Microcal 200+)
7 ½ digit Nanovolt/Microhm
meter (HP-Agilent) |
|

|
| Temperature calibration done as per the
standard test method for calibration of thermocouples by comparison method using
state-of-the-equipment and Master sensors having traceability to NPL, India . |

|
Charges for Calibration
of Thermocouples/Devices/Instruments:
Calibration of
Thermocouples/Devices
S.No. |
Description
|
Parameter/ Range |
Charges Rs. #
|
1 |
Platinum-Rhodium,
Platinum Thermocouples
Type: B/S/R |
Temperature
400 to 1500OC |
2500 |
2 |
Platinum-Rhodium,
Platinum Thermocouples
Type: B/S/R |
Temperature
400 to 1300OC |
2000 |
3 |
Chromel-Alumel
Type K and similar Thermocouples |
Temperature
30 to 1200OC |
1000 |
4 |
Iron-Constantan
Type J:
Thermocouples |
Temperature
30 to 600OC |
1000 |
5 |
Copper-Constantan
Type T
Thermocouples |
Temperature
30 to 400 OC |
750 |
6 |
Resistance
Thermal Detectors Pt. 100 etc. |
Temperature
0 to 600OC |
1000 |
7 |
Dry Block
Calibrators, Ovens, Furnaces etc. (at NML) |
Temperature
30 to 600OC |
3000 |
8 |
Dry Block
Calibrators, Ovens, Furnaces etc. (at NML) |
Temperature
30 to 1450OC |
6000 |
9 |
Dry Block
Calibrators, Ovens, Furnaces etc. (at site) |
Temperature
30 to 1450OC |
Case to Case basis |
*
The above charges are for calibration of up to 6 points. Additional
temperature points will be charged at Rs.150/- each.
|
Calibration of Instruments : |
|
S.No. |
Description
|
Parameter/Range |
Charges, Rs. # |
1 |
Millivolt meter
(source
& measure) |
Voltage
-20 to 200 mV |
750
(per channel) |
2 |
Ohm Meter
(source
& measure) |
Resistance
0 to 500W |
750
(per channel) |
3 |
Temperature
indicators, temperature controllers or both digital and analog |
Temperature
0 to 2200 OC |
750 |
|
On site
calibration of furnaces, ovens, baths etc., besides thermocouples are also
undertaken.
Charges are decided on a case to case basis.
Time required for calibration: 5 working days #
Service Tax 12.36% to be added |
|
Mode of payment: Advance payment in full, DD in
favor of NML Unit, Chennai |
|
For further details, please contact: |
|
Director
Prof. S.P. Mehrotra
NATIONAL METALLURGICAL LABORATORY
(Council of Scientific & Industrial Research)
JAMESHEDPUR 831 007
Phone: (0657) 2271715, 2270092, 2271709-14 (PBX)
Fax: (0657) 2270527, 2271251, 2271159
Email: director@nmlindia.org,
Website: www.nmlindia.org
|
|
Dr. S. Srikanth
Scientist-In-Charge
NML Madras Centre, CSIR Madras Complex
Taramani, CHENNAI 600 113
Ph: 044 2254 2077, 2254 2529, 2254 2523, Fax: 044 2254 1027
Email: nmlmc@vsnl.com
Working hours: 9.00 am to 5.30 pm (Monday to Friday, except
Govt. holidays)
|
|
|
| |
|